PILING AND PILE TESTING WORKS AT US
EMBASSY COMPOUND, ISLAMABAD.
EMBASSY COMPOUND, ISLAMABAD.
TEST PILES & TESTING
Construction of 0.75m & 1.5 meter dia RCC test piles of depth up to 20.25 meter in Islamabad area by kelly bucket drilling.
Pile testing for compressive load up to 600 ton & 1400 tons respectively with installing strain gauge instruments (imported form Geokon-USA) with kentiledge method.
PILE CONSTRUCTION
Construction of 120 No working piles of 0.75 m & 1.5 m dia RCC piles up to 16.25 m & 20.25 m depth by kelly bucket drilling.